Sterilization and Thawing Device (air control type: low temp., high humidity)
Feature
- Thawed while maintaining freshness
Device is kept at low temp. and high humidity, maintaining freshness without dryness
- Very low drip
Reduced drip due to thawing process keeping the surface/inside temperature of the raw materials similar, and maintain umami-nutrients
- Stable thawing process
Even thaw is achieved by having the air flow/direction in the thawing chamber being adjustable per condition of the raw materials
- Long-lasting freshness due to sterilization effect
The sterilization effect during thawing process removes the bacteria inside the thawing chamber
- Maintains freshness
By covering the entire process from thawing to refrigeration storage, keeps the materials fresh, of which can be taken out per work process
- Deodorizing effect
Foul odors are removed upon the air in the thawing chamber coming in contact with the water of the air cleaner
- Also functions as a Ageing-Maturation Chamber
Age livestock meat, etc. by storing it under aseptic conditions with stable temperature and humidity
- Low running cost
Only requires water for humidification, and does not generate sewage and any costs for sewage treatment
Machine Specification
name |
CD-0.5 |
CD-1 |
CD-1.5 |
CD-2 |
CD-3 |
Chamber Temperature |
Standard 2℃~5℃(When refrigerated -2℃~+10℃) |
Chamber Humidity |
85% RH or more |
Internal Temperature of Washing Chamber |
NASA Standard : Above 110,000 class |
Final Thawing Temperature |
Standard -1℃ or less |
Goods Receipt Weight(kg) |
500 |
1,000 |
1,500 |
2,000 |
3,000 |
Number of Carts |
‐ |
‐ |
6 |
9 |
12 |
Number of Steaming Baskets |
24* |
48 |
72 |
108 |
144 |
Thawing Fan |
0.1K×4 units |
0.4K×4 units |
0.4K×6 units |
0.4K×8 units |
0.75K×6 units |
0.4kW |
1.6kW |
2.4kW |
3.2kW |
4.5kW |
Air Cleaner |
MCN400RB |
MCN400RB |
MCN500RB |
MCN500RB |
MCN650RB |
Injection Pump |
0.25kW |
0.25kW |
0.4kW |
0.4kW |
0.75kW |
Humidification Heater |
6kW |
6kW |
10kW |
10kW |
15kW |
Refrigeration Machine |
0.79kW |
1.6kW |
2.3kW |
3.0kW |
Cooler |
0.028kW |
0.14kW |
0.2kW |
0.3kW |
Remote Capacitor |
‐ |
‐ |
‐ |
0.065kW |
External Dimensions(m/m) |
H |
2,400 |
2,400 |
2,820 |
2,820 |
2,820 |
W |
1,150 |
1,800 |
2,700 |
2,820 |
3,600 |
L |
4,300 |
4,800 |
4,600 |
5,500 |
6,000 |
Power Supply |
AC200V |
7.868kW |
9.99kW |
16.05kW |
16.85kW |
24.715kW |
AC100V |
20W(Internal Chamber Lighting)
90W(Antifreeze Heater) |
40W(Internal Chamber Lighting)
90W(Antifreeze Heater) |
name |
CD-4 |
CD-5 |
CD-7 |
CD-10 |
Chamber Temperature |
Standard 2℃~5℃(When refrigerated -2℃~+10℃) |
Chamber Humidity |
85% RH or more |
Internal Temperature of Washing Chamber |
NASA Standard Above 110,000 class |
Final Thawing Temperature |
Standard -1℃ or less |
Goods Receipt Weight(kg) |
4,000 |
5,000 |
7,000 |
10,000 |
Number of Carts |
16 |
20 |
30 |
42 |
Number of Steaming Baskets |
192 |
240 |
360 |
504 |
Thawing Fan |
0.75K×8 units |
1.5K×6 units |
1.5K×8 units |
1.5K×12 units |
6.0kW |
9.0kW |
12kW |
18kW |
Air Cleaner |
MCN650RB |
MCN650RB |
MCN800RB |
MCN950RB |
Injection Pump |
0.75kW |
0.75kW |
0.4kW |
0.75kW |
Humidification Heater |
15kW |
15kW |
Hot water pump 0.25kW |
Hot water pump 0.25kW |
Refrigeration Machine |
3.0kW |
3.75kW |
5.5kW |
Cooler |
0.3kW |
0.4kW |
0.6kW |
Remote Capacitor |
0.065kW |
0.15kW |
0.15kW |
External Dimensions(m/m) |
H |
2,820 |
2,820 |
2,820 |
2,820 |
W |
3,600 |
3,600 |
4,500 |
5,400 |
L |
7,550 |
8,450 |
9,500 |
11,000 |
Power Supply |
AC200V |
26.715kW |
30.15kW |
20.65kW |
30.75kW |
AC100V |
40W(Internal Chamber Lighting)90W(Antifreeze Heater) |
Dimensions: Standard Cart/W800×L1,000×H1,750m/m
Dimensions: Steaming Basket/W680×L1,040m/m* W790×L900m/m
CD-7 and CD-10 air purifiers are for hot water boiler specifications(Hot water boiler 60,000kW/H)
Work Method
Feed raw materials on carts etc. and set in the chamber |
|
Set thawing time and temperature using the control panel (time and temperature will vary depending on the raw material) |
|
After completing thawing process, chamber will automatically switch to refrigeration mode, and the thawed materials can be stored until the next work process |
Ownership of Construction
Patent |