Sterilization and Thawing Device (air control type: low temp., high humidity)

Feature

  • Thawed while maintaining freshness
    Device is kept at low temp. and high humidity, maintaining freshness without dryness
  • Very low drip
    Reduced drip due to thawing process keeping the surface/inside temperature of the raw materials similar, and maintain umami-nutrients
  • Stable thawing process
    Even thaw is achieved by having the air flow/direction in the thawing chamber being adjustable per condition of the raw materials
  • Long-lasting freshness due to sterilization effect
    The sterilization effect during thawing process removes the bacteria inside the thawing chamber
  • Maintains freshness
    By covering the entire process from thawing to refrigeration storage, keeps the materials fresh, of which can be taken out per work process
  • Deodorizing effect
    Foul odors are removed upon the air in the thawing chamber coming in contact with the water of the air cleaner
  • Also functions as a Ageing-Maturation Chamber
    Age livestock meat, etc. by storing it under aseptic conditions with stable temperature and humidity
  • Low running cost
    Only requires water for humidification, and does not generate sewage and any costs for sewage treatment

Machine Specification

name CD-0.5 CD-1 CD-1.5 CD-2 CD-3
Chamber Temperature Standard 2℃~5℃(When refrigerated -2℃~+10℃)
Chamber Humidity 85% RH or more
Internal Temperature of Washing Chamber NASA Standard : Above 110,000 class
Final Thawing Temperature Standard -1℃ or less
Goods Receipt Weight(kg) 500 1,000 1,500 2,000 3,000
Number of Carts 6 9 12
Number of Steaming Baskets 24* 48 72 108 144
Thawing Fan 0.1K×4 units 0.4K×4 units 0.4K×6 units 0.4K×8 units 0.75K×6 units
0.4kW 1.6kW 2.4kW 3.2kW 4.5kW
Air Cleaner MCN400RB MCN400RB MCN500RB MCN500RB MCN650RB
Injection Pump 0.25kW 0.25kW 0.4kW 0.4kW 0.75kW
Humidification Heater 6kW 6kW 10kW 10kW 15kW
Refrigeration Machine 0.79kW 1.6kW 2.3kW 3.0kW
Cooler 0.028kW 0.14kW 0.2kW 0.3kW
Remote Capacitor 0.065kW
External Dimensions(m/m) 2,400 2,400 2,820 2,820 2,820
1,150 1,800 2,700 2,820 3,600
4,300 4,800 4,600 5,500 6,000
Power Supply AC200V 7.868kW 9.99kW 16.05kW 16.85kW 24.715kW
AC100V 20W(Internal Chamber Lighting)
90W(Antifreeze Heater)
40W(Internal Chamber Lighting)
90W(Antifreeze Heater)

 

name CD-4 CD-5 CD-7 CD-10
Chamber Temperature Standard 2℃~5℃(When refrigerated -2℃~+10℃)
Chamber Humidity 85% RH or more
Internal Temperature of Washing Chamber NASA Standard Above 110,000 class
Final Thawing Temperature Standard -1℃ or less
Goods Receipt Weight(kg) 4,000 5,000 7,000 10,000
Number of Carts 16 20 30 42
Number of Steaming Baskets 192 240 360 504
Thawing Fan 0.75K×8 units 1.5K×6 units 1.5K×8 units 1.5K×12 units
6.0kW 9.0kW 12kW 18kW
Air Cleaner MCN650RB MCN650RB MCN800RB MCN950RB
Injection Pump 0.75kW 0.75kW 0.4kW 0.75kW
Humidification Heater 15kW 15kW Hot water pump 0.25kW Hot water pump 0.25kW
Refrigeration Machine 3.0kW 3.75kW 5.5kW
Cooler 0.3kW 0.4kW 0.6kW
Remote Capacitor 0.065kW 0.15kW 0.15kW
External Dimensions(m/m) 2,820 2,820 2,820 2,820
3,600 3,600 4,500 5,400
7,550 8,450 9,500 11,000
Power Supply AC200V 26.715kW 30.15kW 20.65kW 30.75kW
AC100V 40W(Internal Chamber Lighting)90W(Antifreeze Heater)

Dimensions: Standard Cart/W800×L1,000×H1,750m/m
Dimensions: Steaming Basket/W680×L1,040m/m* W790×L900m/m
CD-7 and CD-10 air purifiers are for hot water boiler specifications(Hot water boiler 60,000kW/H)

Work Method

Feed raw materials on carts etc. and set in the chamber Set thawing time and temperature using the control panel (time and temperature will vary depending on the raw material) After completing thawing process, chamber will automatically switch to refrigeration mode, and the thawed materials can be stored until the next work process

Ownership of Construction

Patent 1844484,1318287,1704135